Solutions to the interference of horizontal stripes and stripes in surveillance images
Distinguish the three types of causes of electromagnetic interference, power interference and ground loops, and provide targeted troubleshooting and treatment plans.
Determine the type of interference first
| Phenomena | Possible reasons |
|---|---|
| Slowly scrolling thick horizontal bar | Ground loop/power interference (power frequency 50Hz) |
| Fine twill, water ripples | High frequency electromagnetic interference (inverters, elevators, motors) |
| Network, snowflakes | Line attenuation, poor contact, network cable quality problems |
| The screen changes as the equipment starts and stops | The power supply shares the circuit of high-power equipment |
| Only some lines have problems | There is a problem with the cable or connector of this line |
| All roads have problems | Shared power supply, grounding or central equipment problems |
Ground loop interference (most common)
When the ground potential of the camera and the back-end equipment are inconsistent, a circulating current will form in the shielding layer of the signal line, resulting in 50Hz power frequency interference. Appears as a horizontal bar that slowly scrolls up and down.
Solution:
- Do single-point grounding to avoid multiple-point grounding loops.
- Check whether the camera casing, bracket, pole, and equipment box form multiple grounding points.
- Install a ground loop isolator (video isolation transformer) and the effect will be immediate.
- Use an isolated PoE switch or optocoupler isolation.
Electromagnetic interference
- Keep a distance (≥30cm) between network cables and strong electricity, avoid running parallel cables, and make them vertical when crossing.
- Use shielded network cable (STP), and connect both ends of the shielding layer to ground reliably.
- The metal conduits/bridges are fully connected to the ground.
- Stay away from frequency converters, traction machines, transformers, and high-power motors.
- When the interference is extremely strong, use fiber transmission to fundamentally solve the problem.
Power Interference
- The monitoring equipment has an independent power supply circuit and is not mixed with elevators, air conditioners, and lighting.
- Use high-quality regulated power supplies and adapters to avoid inferior switching power supplies.
- Pay attention to the voltage drop when providing centralized power supply, and the terminal voltage must meet the equipment requirements.
- Install an AC filter or isolation transformer.
- Configure UPS to improve power supply quality.
Troubleshooting steps
- First confirm whether it is a single channel or all, and narrow down the scope.
- Move the suspicious camera to the computer room and connect it directly with a short network cable for testing. If it disappears, it is a problem with the on-site line/environment.
- Disconnect other devices to determine whether they affect each other.
- Temporarily change the optical fiber or add an isolator to verify whether it is a ground loop or electromagnetic interference.
- After rectification, continue to observe for 24 to 48 hours before accepting.
Related content
Linkage integration of video surveillance, access control, and alarm systems: interface methods and implementation points
09-19
Moiré and false color in surveillance images: lens and sensor matching issues
09-18
Progressive transformation from analog to network: reusing coaxial and hybrid networking solutions
09-17
Lens dirt and protective window cleaning: invisible causes of image quality degradation
09-16
Surveillance video as evidence: retrieval process, preservation and legal effect
09-15
Permission classification and desensitization of video data: who can watch and who can export
09-14
Security system level protection: What requirements should the video surveillance part meet?
09-13
Computer room dynamic environment monitoring: temperature and humidity, mains power, water leakage and smoke detector access
09-12